EB1O_1V115 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 240V AC/96V DC | 40A | 50/60Hz | 10,000 A @ 240 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V114 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 30A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V113 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 25A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V112 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 20A | 50/60Hz | 14,000 A @ 277 V AC, 14,000 A @ 480 V AC, 14,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V111 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 15A | 50/60Hz | 14,000 A @ 277 V AC, 14,000 A @ 480 V AC, 14,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V110 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 10A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V109 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 8A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V108 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 6A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V107 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 5A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V106 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 4A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V105 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 3A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V104 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 2A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V103 | D Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 1A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V67 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 240V AC/96V DC | 63A | 50/60Hz | 10,000 A @ 240 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V66 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 240V AC/96V DC | 50A | 50/60Hz | 10,000 A @ 240 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V65 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 240V AC/96V DC | 40A | 50/60Hz | 10,000 A @ 240 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V64 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 240V AC/96V DC | 35A | 50/60Hz | 10,000 A @ 240 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V63 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 32A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V62 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 30A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V61 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 25A | 50/60Hz | 14,000 A @ 277 V AC, 14,000 A @ 480 V AC, 14,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V60 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 20A | 50/60Hz | 14,000 A @ 277 V AC, 14,000 A @ 480 V AC, 14,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V59 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 125V DC/250V DC | 20A | 50/60Hz | 10,000 A @ 125 V DC, 10,000 A @ 250 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V58 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 16A | 50/60Hz | 14,000 A @ 277 V AC, 14,000 A @ 480 V AC, 14,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V57 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 15A | 50/60Hz | 14,000 A @ 277 V AC, 14,000 A @ 480 V AC, 14,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V56 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 125V DC/250V DC | 15A | 50/60Hz | 10,000 A @ 125 V DC, 10,000 A @ 250 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V55 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 13A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V54 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 10A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V53 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 125V DC/250V DC | 10A | 50/60Hz | 10,000 A @ 125 V DC, 10,000 A @ 250 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V52 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 8A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |
EB1O_1V51 | C Trip Type | 2 Pole—Toggle Style | 104.90mm | 59.94mm | 35.56mm | -10° to 165° | Screw-Clamp Terminals | --- | --- | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 277V AC/480YV AC/96V DC | 7A | 50/60Hz | 10,000 A @ 277 V AC, 10,000 A @ 480 V AC, 10,000 A @ 96 V DC | 35mm | --- |
x DIN-Rail Mount Branch Circuit Breakers Estimated Delivery - 15 to 17 days |