| EA1B3_4V16 |
Power and Signal Wire—Stranded Double Shielded |
1,000V AC/1,000V DC |
6 |
75 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
1.52m |
Polyethylene Plastic |
-40° to 220° F |
4 |
--- |
6/4 (Signal Wire-14/2) |
Flexible |
Motors, Interference Shielding |
26.16 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V15 |
Power and Signal Wire—Stranded Double Shielded |
1,000V AC/1,000V DC |
8 |
55 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
1.52m |
Polyethylene Plastic |
-40° to 220° F |
4 |
--- |
8/4 (Signal Wire-18/2) |
Flexible |
Motors, Interference Shielding |
24.38 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V14 |
Power and Signal Wire—Stranded Double Shielded |
1,000V AC/1,000V DC |
10 |
40 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
1.52m |
Polyethylene Plastic |
-40° to 220° F |
4 |
--- |
10/4 (Signal Wire-14/2) |
Flexible |
Motors, Interference Shielding |
18.80 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V13 |
Power and Signal Wire—Stranded Double Shielded |
1,000V AC/1,000V DC |
12 |
30 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
1.52m |
Polyethylene Plastic |
-40° to 220° F |
4 |
--- |
12/4 (Signal Wire-18/2) |
Flexible |
Motors, Interference Shielding |
16.51 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V12 |
Power and Signal Wire—Stranded Double Shielded |
1,000V AC/1,000V DC |
12 |
30 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
1.52m |
Polyethylene Plastic |
-40° to 220° F |
4 |
--- |
12/4 (Signal Wire-14/2) |
Flexible |
Motors, Interference Shielding |
17.02 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V11 |
Power and Signal Wire—Stranded Double Shielded |
1,000V AC/1,000V DC |
14 |
25 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
1.52m |
Polyethylene Plastic |
-40° to 220° F |
4 |
--- |
14/4 (Signal Wire-18/2) |
Flexible |
Motors, Interference Shielding |
15.75 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V10 |
Power and Signal Wire—Stranded Double Shielded |
1,000V AC/1,000V DC |
14 |
25 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
1.52m |
Polyethylene Plastic |
-40° to 220° F |
4 |
--- |
14/4 (Signal Wire-14/2) |
Flexible |
Motors, Interference Shielding |
16.00 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V9 |
Power and Signal Wire—Stranded Double Shielded |
1,000V AC/1,000V DC |
16 |
18 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
1.52m |
Polyethylene Plastic |
-40° to 220° F |
4 |
--- |
16/4 (Signal Wire-18/2) |
Flexible |
Motors, Interference Shielding |
14.48 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V8 |
Power Wire—Stranded Double Shielded |
1,000V AC/1,500V DC |
4 |
70 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
0.3m |
PVC Plastic |
-40° to 220° F |
4 |
Nylon Plastic/PVC Plastic |
4/4 |
Flexible |
Motors, Interference Shielding |
30.23 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V7 |
Power Wire—Stranded Double Shielded |
1,000V AC/1,500V DC |
6 |
55 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
0.3m |
PVC Plastic |
-40° to 220° F |
4 |
Nylon Plastic/PVC Plastic |
6/4 |
Flexible |
Motors, Interference Shielding |
25.40 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V6 |
Power Wire—Stranded Double Shielded |
1,000V AC/1,500V DC |
8 |
40 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
0.3m |
PVC Plastic |
-40° to 220° F |
4 |
Nylon Plastic/PVC Plastic |
8/4 |
Flexible |
Motors, Interference Shielding |
21.34 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V5 |
Power Wire—Stranded Double Shielded |
1,000V AC/1,500V DC |
10 |
30 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
0.3m |
PVC Plastic |
-40° to 220° F |
4 |
Nylon Plastic/PVC Plastic |
10/4 |
Flexible |
Motors, Interference Shielding |
17.78 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V4 |
Power Wire—Stranded Double Shielded |
1,000V AC/1,500V DC |
12 |
20 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
0.3m |
PVC Plastic |
-40° to 220° F |
4 |
Nylon Plastic/PVC Plastic |
12/4 |
Flexible |
Motors, Interference Shielding |
14.73 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V3 |
Power Wire—Stranded Double Shielded |
1,000V AC/1,500V DC |
14 |
15 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
0.3m |
PVC Plastic |
-40° to 220° F |
4 |
Nylon Plastic/PVC Plastic |
14/4 |
Flexible |
Motors, Interference Shielding |
13.21 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V2 |
Power Wire—Stranded Double Shielded |
1,000V AC/1,500V DC |
16 |
10 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
0.3m |
PVC Plastic |
-40° to 220° F |
4 |
Nylon Plastic/PVC Plastic |
16/4 |
Flexible |
Motors, Interference Shielding |
11.68 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|
| EA1B3_4V1 |
Power Wire—Stranded Double Shielded |
1,000V AC/1,500V DC |
18 |
7 A @ 86° F |
UL Listed, C-UL Listed, Flame Rated FT4 |
Black |
0.3m |
PVC Plastic |
-40° to 220° F |
4 |
Nylon Plastic/PVC Plastic |
18/4 |
Flexible |
Motors, Interference Shielding |
9.91 |
--- |
WTTC |
x
Motor Cable
Estimated Delivery - 15 to 17 days
|