EA1A4_1V13 | Stranded Wire | 600V AC | 8 | 320/32 | 80 A @ 86° F | CSA Certified, UL Recognized Component, Flame Rated VW-1 | Black | 3.04m | PVC Plastic Outer Insulation with Cloth Tape and PVC Plastic Inner Insulation | -45° to 190° F | Continuous Flex | 9.14 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V12 | Stranded Wire | 600V AC | 10 | 186/32 | 55 A @ 86° F | CSA Certified, UL Recognized Component, Flame Rated VW-1 | Black | 3.04m | PVC Plastic Outer Insulation with Cloth Tape and PVC Plastic Inner Insulation | -45° to 190° F | Continuous Flex | 7.37 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V11 | Stranded Wire | 600V AC | 12 | 224/34 | 40 A @ 86° F | CSA Certified, UL Recognized Component, Flame Rated VW-1 | Black | 3.04m | PVC Plastic Outer Insulation with Cloth Tape and PVC Plastic Inner Insulation | -45° to 190° F | Continuous Flex | 6.60 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V10 | Stranded Wire | 600V AC | 14 | 140/34 | 35 A @ 86° F | CSA Certified, UL Recognized Component, Flame Rated VW-1 | Black | 3.04m | PVC Plastic Outer Insulation with Cloth Tape and PVC Plastic Inner Insulation | -45° to 190° F | Continuous Flex | 5.84 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V9 | Stranded Wire | 600V AC | 18 | 420/44 | 7 A @ 86° F | UL Recognized Component | Black,Green,Red,White | 3.04m | PVC Plastic Outer Insulation | -40° to 175° F | Continuous Flex | 1.78 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V8 | Stranded Wire | 600V AC | 20 | 266/44 | 4.8 A @ 86° F | UL Recognized Component | Black,Green,Red,White | 3.04m | PVC Plastic Outer Insulation | -40° to 175° F | Continuous Flex | 1.52 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V7 | Stranded Wire | 600V AC | 22 | 168/44 | 2.8 A @ 86° F | UL Recognized Component | Black,Green,Red,White | 3.04m | PVC Plastic Outer Insulation | -40° to 175° F | Continuous Flex | 1.27 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V6 | Stranded Wire | 600V AC | 24 | 105/44 | 2 A @ 86° F | UL Recognized Component | Black,Green,Red,White | 3.04m | PVC Plastic Outer Insulation | -40° to 175° F | Continuous Flex | 1.27 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V5 | Stranded Wire | 600V AC | 26 | 66/44 | 1.3 A @ 86° F | UL Recognized Component | Black,Green,Red,White | 3.04m | PVC Plastic Outer Insulation | -40° to 175° F | Continuous Flex | 1.02 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V4 | Stranded Wire | 600V AC | 28 | 42/44 | 0.8 A @ 86° F | UL Recognized Component | Black,Green,Red,White | 3.04m | PVC Plastic Outer Insulation | -40° to 175° F | Continuous Flex | 1.02 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V3 | Stranded Wire | 600V AC | 30 | 28/44 | --- | UL Recognized Component | Black,Green,Red,White | 3.04m | PVC Plastic Outer Insulation | -40° to 175° F | Continuous Flex | 0.76 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V2 | Stranded Wire | 300V AC | 32 | 18/44 | 0.3 A @ 86° F | UL Recognized Component | Black,Green,Red,White | 3.04m | PVC Plastic Outer Insulation | -40° to 175° F | Continuous Flex | 0.51 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |
EA1A4_1V1 | Stranded Wire | 150V AC | 36 | 7/44 | 0.1 A @ 86° F | UL Recognized Component | Black,Green,Red,White | 3.04m | PVC Plastic Outer Insulation | -40° to 175° F | Continuous Flex | 0.51 |
x Continuous-Flex Wire Estimated Delivery - 15 to 17 days |